Trans TOOL

2023-08-31

Shifting the tibial tuberosity using the Trans TOOL.

{ Article for the journal Modern Veterinary Clinic 2023 } 


Patellar luxation is a condition in which the patella, instead of moving anatomically in the intercondylar groove, falls out of it and dislocation occurs.

Medial dislocation is most common, although lateral luxation is also seen. It occurs in all dog breeds, but it is much more common in small and miniature breeds.

One of the most popular treatments for a patellar luxation is to shift the tibial tuberosity. It consists in incomplete, vertical cutting of the tibia, similarly to the TTA procedure (Tibial Tuberosity Advancement) and its displacement in the frontal plane.

The cut is made in 30 percent of the total width of the tibia in the lateral view.

During preoperative planning, the surgeon predetermines the required offset distance, but this requires intraoperative verification. Maintaining the required shift during the test using the hand is difficult and imprecise, while stabilizing the tuberosity after transposition with the implant makes it difficult to correct it in the event of further abnormal movement of the patella in the patellofemoral groove.

In this case, we need to remove the implant, increase the offset distance, and reinsert the implant in a different location. This leaves unnecessary bone loss and limits the number of attempts we can make.

The solution to this problem is the use of the Trans TOOL - a special device for the transposition of the tibial tuberosity, which enables precise performance of the procedure and checking its effect during the operation. This instrument is available in four different sizes.

Depending on the size of the patient, we can choose one of four systems:

1.5 / 2.0 (miniature and small breeds), 2.4 / 2.7 (medium breeds) and 3,5 (large breeds).



Patellar luxation is a condition in which the patella instead of moving anatomically in the intercondylar groove dislocates from it, resulting in luxation.

The most common luxation occurs medially, although there are also cases of lateral luxation.
It occurs in all dog breeds, but this condition is significantly more common in small and miniature breeds.  

One of the most popular methods for treating patellar luxation is the shifting of the tibial tuberosity. This involves a partial, vertical cut of the tibia similar to the TTA procedure (Tibial Tuberosity Advancement) and moving it in the frontal plane.    

The cut is made at 30 percent of the total width of the tibia in the lateral view.

During preoperative planning, the surgeon preliminarily determines the distance of the required shift, but this requires intraoperative verification.
Maintaining the required shift during the test using hands is difficult and imprecise, while stabilizing the tuberosity after transposition using an implant complicates any correction in case of further abnormal patella movement in the patellofemoral groove.

In such a case, we must remove the implant, increase the distance of the shift, and reintroduce the implant in a different location.
This leaves unnecessary bone tissue loss and limits the number of attempts we can make.       

The solution to this problem is the use of the Trans TOOL - a special device for the transposition of the tibial tuberosity, which allows for precise execution of the procedure and checking its effect during the operation.  This device is available in four different sizes. 

Depending on the size of the patient, we can choose one of four systems: 

1.5 and 2.0 (miniature and small breeds), 2.4/2.7 (medium breeds) and 3.5 (large breeds).


UE Podlaskie_800x90px